Valves, Fittings & Tubings - Fittings 1550 bar

MAXIMATOR fittings and gland assemblies of the 1,550 bar series are designed for simple and safe connection of HP pipes up to a max. pressure of 1,550 bar.

Generell informasjon

Web Catalogue VFT-Chapter 2 - Medium Pressure.pdf
Web Catalogue VFT-Chapter 2 - Medium Pressure.pdf
Medium Pressure Valves, Fittings and Tubings; 1,500 bar; 21,000 psi; Coned and Threaded Nipples; O-Ring Check Valves; Ball Check Valves; Anti Vibration Collet Gland Assemblies; Line Filters; Safety Head Assemblies; Rupture Discs

MAXIMATOR fittings and gland assemblies of the 1,550 bar series are designed for simple and safe connection of HP pipes up to a max. pressure of 1,550 bar.

All gland assemblies are fit for multiple use. Fittings are supplied complete with collars and glands.

Anti-vibration gland assemblies may be used to achieve permanent connections even under extreme mechanical loads.

MAXIMATOR fittings and gland assemblies are compatible with HP systems made by other manufacturers.

Technical data:

Body material 316 L (1.4404)
Collar material 316 L (1.4404)
Gland material 316 L (1.4404)
Temperature -50°C to +350°C
Connections 4MF, 6MF, 9MF, 12MF, 16MF