Maximator

Brochure

MAXIMATOR High Pressure Pumps
3999.0467, Language: English, Release: 04/2007

Contact

MAXPRO Technologies Inc.
sales@maxprotech.com
Telephone: +001 814-474-9191
Contact
MAXIMATOR Test, LLC
service@maximator-test.com
Telephone: 847.855.2700
Contact

High Pressure Pumps - M...D series

  • double acting
  • single air drive head
  • Pressures to 2,200 bar (31,900 psi)

Overview

Type i* Displacement volume Displacement volume P max.* P max.* Flow Flow
cm³ in³ bar psi cfm l/min
M22D 1:28 9,20 0,56 280 4060 0,14 3,91
M37D 1:46 5,60 0,34 460 6670 0,08 2,35
M72D 1:86 3,00 0,18 860 12470 0,04 1,24
M111D 1:130 2,00 0,12 1300 18850 0,03 0,82
M189D 1:220 1,20 0,07 2200 31900 0,02 0,49
i = Pressure ratio
P max. = Discharge

MAXIMATOR GmbH | Lange Straße 6 | 99734 Nordhausen | Fon 03631 9533-0 | E-Mail: info@maximator.de